Procedure (coordinates X, Y)
There are three methods for determining coordinates:
Point and target grid
(automatic version that orients itself to the target grid)
Point & point
(manual version without target in which two reference points are established)
SmartGrid
(automatic variant based on
SmartGrid
, where the reference point, orientation and units
are learned)
Point and target grid
1.
Place the desired target grid with world coordinate system orientation into the Vision Sensor's field of
view. If a
SmartGrid is
used for this purpose, only the chessboard pattern is used; other information
(reference point, orientation, units) is ignored.
2.
Press the
Edit button
.
3.
Select the
Point and target grid method.
4.
Press the
Teach
button.
The grid points will be programmed and marked with a small orange cross. A reference point will
also be inserted.
NOTE
Should this teaching fail, a user defined coordinate system could be programmed.
Causes could be:
-
The target squares are too small (minimum size 20 x 20 pixels)
-
There are too few squares in the field of view (at least 5 x 7 squares are required,
preferably more)
-
The target is partially covered
5.
Drag the reference point onto a grid point of your choice.