Technical Documentation
VeriSens
®
v2.11.0-B4
306/429
Baumer Optronic GmbH
Radeberg, Germany
15.4 Available commands for TCP / UDP / RS485
15.4.1 CS command
– reset statistics
This function enables you to reset the statistics for individual jobs.
Example
Structure of the command
PLC
device
Command
Parameters
C
S
0
0
0
0
C
lear
S
tatistics
4 byte ASCII hex
Job number
0000 = active job
0001
– 0010 = Job number 1-16
0011
– 00FF = invalid
Structure of the Response
PLC
device
Response
R
C
0
0
0
0
R
esponse
Statistics
C
leared
4 byte ASCII hex
Job number
0000 = active job
0001
– 0010 job number 1-16
0011
– 00FF = invalid