![Baumer VeriSens CS Series Скачать руководство пользователя страница 364](http://html.mh-extra.com/html/baumer/verisens-cs-series/verisens-cs-series_technical-documentation-manual_2710941364.webp)
Technical Documentation
VeriSens
®
v2.11.0-B4
364/429
Baumer Optronic GmbH
Radeberg, Germany
15.5.4.5.2
Module: Result data
Input data (device
PLC)
Byte
Data element
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Handshake for
input data
pad (0)
D -> C
HS
Flag
pad (0)
D -> C
HSWA
ACT
ACK
D -> C
HSS
ACT
ACK
1 … 2 Actual
Length
Result data
Act Res Data Len
3
…
Result data
Result data (4/8/16/32/64/128/250 byte)
Output data (PLC
device)
Byte
Data element
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Handshake for
input data
pad (0)
D -> C
HS
ACK
pad (0)
D -> C
HSWA
ACT
D -> C
HSS
ACT
15.5.4.5.3
Module: Parameters
Input data (device
PLC)
Byte
Data element
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Handshake for
output data
pad (0)
C -> D
HS
ACK
pad (0)
C -> D
HSWA
ACT
ACK
C -> D
HSS
ACT
ACK
Output data (PLC
device)
Byte
Data element
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Handshake for
output data
pad (0)
C -> D
HS
Flag
pad (0)
C -> D
HSWA
ACT
C -> D
HSS
ACT
1
…
2
Actual
length of the
Parameters
Act Parameters Len
3
…
Parameters
Parameters (4/8/16/32/64/128/250 byte)