Four LEDs indicate the state of the 2 ISDN lines. LED B1 and B2 indicate the status of ISDN Line 1, B3 and
B4 the status of ISDN Line 2. When an ISDN line is connected to the network the associated channel LEDs will
show Red. When a call is active on one of the ISDN lines the associated channel LED will show Green. If an
ISDN line is not connected or has failed to initialize with the network the associated LED will be not be illumi-
nated.
Note
: If you are using a North American ISDN Protocol a Red LED will indicate that SPID (
S
ervice
P
rofile
ID
entifier) has correctly initialized with the network
4.4.3. ISDN/IP/SIP Fast Dial (FD0 and FD1 only)
This feature enables an extremely fast call setup for two regularly used or priority destinations. These must be
programmed in ISDN or IP speed dial locations 0 and 1. A single touch of key FD0 or FD1 initiates the fast call
sequence for either of these two locations. The unit will be configured according to the ISDN or IP speed dial
which will specify the ISDN numbers to dial or IP Address to use, and the audio profile to use.
4.5. Rear Panel Connectors
The WorldCast Equinox should be completely wired before placing the circuit into service. The WorldCast
Equinox comes pre-configured ready to run back-to-back test loops.
udio configuration screen
Press the key to move to the
Audio I/O
option and press
Ent
. You are then presented with a choice of ei-
ther analog or digital audio
– select the appropriate entry and press
Ent
.
Audio connectors on rear panel
* The IDSN debug port is used to trouble shoot potential ISDN problems. Call technical support if such prob-
lems were to arise.
Power supply rear panel details
4.5.1. Power Supply
IEC AC Inlet
The AC interface is supplied in an IEC inlet and allows the con-
nection of a suitable AC supply between 90
V and 260
V AC. This
inlet also holds the AC mains fuse. Please refer to the safety in-
structions for replacement.
Two inlets are available with the redundant PSU option.
Audio analog
inputs
Audio analog
outputs
Audio digital
input
AES/EBU
digital ref in
AES/EBU
output
Alarm
output
Opto-isolator
inputs
LAN/IP
interface
X.21/V.35
DTE
Aux
data port
ISDN
interface
Power sockets (2 with
redundant PSU option)
Debug
SD Card
Backup (op-
tional)
USB slot (op-
tional)
LAN interface
(optional)