CH01V-01
B00844
Pivot Bolt
Adjusting Bolt
Adjusting
Lock Bolt
B00887
-
CHARGING
GENERATOR
CH-7
1246
Author:
Date:
2001 SIENNA (RM787U)
REMOVAL
1.
REMOVE DRIVE BELT
Loosen the pivot bolt, adjusting lock bolt and adjusting bolt, and
remove the drive belt.
Torque:
Pivot bolt: 56 N·m (570 kgf·cm, 41 ft·lbf)
Lock bolt: 18 N·m (180 kgf·cm, 13 ft·lbf)
2.
REMOVE GENERATOR
(a)
Disconnect the generator connector.
(b)
Remove the nut, and disconnect the generator wire.
(c)
Disconnect the wire harness from the clip.
(d)
Remove the pivot bolt, plate washer, adjusting lock bolt
and generator.