ST01B-04
P10584
Ohmmeter
Continuity
P10585
Ohmmeter
No Continuity
P10586
P10587
ST0040
ST-8
-
STARTING
STARTER
1226
Author:
Date:
2001 SIENNA (RM787U)
INSPECTION
1.
INSPECT COMMUTATOR FOR OPEN CIRCUIT
Using an ohmmeter, check that there is continuity between the
segments of the commutator.
If there is no continuity between any segment, replace the ar-
mature.
2.
INSPECT COMMUTATOR FOR GROUND
Using an ohmmeter, check that there is no continuity between
the commutator and armature coil core.
If there is continuity, replace the armature.
3.
INSPECT COMMUTATOR FOR DIRTY AND BURNT
SURFACES
If the surface is dirty or burnt, correct it with sandpaper (No.400)
or on a lathe.
4.
INSPECT COMMUTATOR CIRCLE RUNOUT
(a)
Place the commutator on V-blocks.
(b)
Using a dial gauge, measure the circle runout.
Maximum circle runout: 0.05 mm (0.0020 in.)
If the circle runout is greater than maximum, correct it on a lathe.
5.
INSPECT COMMUTATOR DIAMETER
Using a vernier caliper, measure the commutator diameter.
Standard diameter: 30.0 mm (1.181 in.)
Minimum diameter: 29.0 mm (1.142 in.)
If the diameter is less than minimum, replace the armature.
6.
INSPECT UNDERCUT DEPTH
Check that the undercut depth is clean and free of foreign mate-
rials. Smooth out the edge.
Standard undercut depth: 0.6 mm (0.024 in.)
Minimum undercut depth: 0.2 mm (0.008 in.)
If the undercut depth is less than minimum, correct it with a
hacksaw blade.