D10342
ON
ODMS
(+)
(-)
D10343
ON
ODLP
(+)
(-)
DI-206
-
DIAGNOSTICS
AUTOMATIC TRANSAXLE
360
Author:
Date:
2001 SIENNA (RM787U)
4
Check voltage between terminal ODMS of ECM and body ground.
PREPARATION:
Turn the ignition switch ON.
CHECK:
Check voltage between terminal ODMS of ECM and body
ground when O/D main switch is ON and OFF.
OK:
O/D main switch
Specified voltage
Press continuously O/D main switch
Below 1.0 V
Release O/D main switch
10 - 14 V
OK
Check and replace the ECM (See page
NG
5
Check voltage between terminal ODLP of ECM and body ground.
PREPARATION:
(a)
Disconnect the connector of ECM.
(b)
Turn the ignition switch ON.
CHECK:
Check voltage between terminal ODLP of ECM and body
ground.
OK:
Voltage: 7.5 - 14 V
OK
Check and replace the ECM (See page
NG
Check and replace harness and connector between combination meter and ECM, O/D main
switch and ECM, O/D main switch and body ground (See page
).