INSPECTION
1.
INSPECT POWER SLIDE DOOR MAIN SWITCH CON-
TINUITY
Switch position
Tester connection
Specified condition
Switch ON
1 - 3
Continuity
Switch OFF
1 - 3
No Continuity
Illumination circuit
4 - 5
Continuity
If continuity is not as specified, replace the switch.
2.
INSPECT POWER SLIDE DOOR RH SIDE CONTROL
FRONT SWITCH CONTINUITY
Switch position
Tester connection
Specified condition
Switch ON
5 - 8
Continuity
Switch OFF
5 - 8
No continuity
Illumination circuit
2 - 6
Continuity
If continuity is not as specified, replace the switch.
3.
INSPECT POWER SLIDE DOOR LH SIDE CONTROL
FRONT SWITCH CONTINUITY
Switch position
Tester connection
Specified condition
Switch ON
3 - 6
Continuity
Switch OFF
3 - 6
No continuity
Illumination circuit
1 - 4
Continuity
If continuity is not as specified, replace the switch.
4.
INSPECT POWER SLIDE DOOR CONTROL SWITCH
CONTINUITY
Switch position
Tester connection
Specified condition
Switch ON
1 - 5
Continuity
Switch OFF
1 - 5
No continuity
Illumination circuit
2 - 4
Continuity
If continuity is not as specified, replace the switch.
5.
INSPECT SLIDE DOOR LOCK RELEASE ACTUATOR
OPERATION
Connect the positive (+) lead from the battery to terminal 2 and
the negative (-) lead to terminal 1, and check the door lock re-
lease link moves to release position.