SF14H-02
B08661
Ohmmeter
Continuity
B08662
Ohmmeter
No Continuity
B08663
Air
E
F
B08664
Battery
Air
E
F
-
SFI
VSV FOR PRESSURE SWITCHING VALVE
SF-75
1150
Author:
Date:
2001 SIENNA (RM787U)
INSPECTION
1.
REMOVE VSV
2.
INSPECT VSV FOR OPEN CIRCUIT
Using an ohmmeter, check that there is continuity between the
terminals.
Resistance:
At 20
°
C (
68°
F)
37 - 44
Ω
At 120
°
C (
248°
F)
51 - 62
Ω
If there is no continuity, replace the VSV.
3.
INSPECT VSV FOR GROUND
Using an ohmmeter, check that there is no continuity between
each terminal and the body.
If there is continuity, replace the VSV.
4.
INSPECT VSV OPERATION
(a)
Check that air does not flow from ports E to F.
(b)
Apply battery positive voltage across the terminals.
(c)
Check that air flows from ports E to F.
If operation is not as specified, replace the VSV.
5.
REINSTALL VSV