MASS AIR FLOW (MAF) METER
SF-35
1110
Author:
Date:
2001 SIENNA (RM787U)
INSPECTION
1.
INSPECT MAF METER RESISTANCE
Using an ohmmeter, measure the resistance between terminals
THA and E2.
Resistance:
Terminals
Resistance
Temperature
THA - E2
13.6 - 18.4 k
Ω
-20
°
C (-4
°
F)
THA - E2
2.21 - 2.69 k
Ω
20
°
C (68
°
F)
THA - E2
0.49 - 0.67 k
Ω
60
°
C (140
°
F)
If the resistance is not as specified, replace the MAF meter.
2.
INSPECT MAF METER OPERATION
(a)
Connect the MAF meter connector.
(b)
Turn the ignition switch ON.
(c)
Using a voltmeter, connect the positive (+) tester probe to
terminal VG, and negative (-) tester probe to terminal
E2G.
(d)
Blow air into the MAF meter, and check that the voltage
fluctuates.
If operation is not as specified, replace the MAF meter.
(e)
Turn the ignition switch LOCK.
(f)
Disconnect the MAF meter connector.