STE 85412
– 11-13 –
TP3000
OPERATOR’S MANUAL
series Robot Controller
The Enable switch is released (lightly grip the Enable switch).
Position the cursor on the axis you want to release the brake, and control the motor
brake.
The motor brake at the axis specified in [LOCK] mode is locked.
The motor brake at the axis specified in [FREE] mode is released.
Cautions
The I/O signal status is indicated by illuminated green lamps for closed contacts
(ON) and by unlit green lamps for open contacts (OFF).
The DIN and DOUT signals are shown 10 points on each line, delimited by groups
of five points, and the number of the signal at the head of the signal string is
displayed at the left end of the line.
The number of DIN and DOUT signal points displayed per page is 64 points.
The edited motor brake information is enabled when the [MOTOR BRAKE
CONTROL screen] is displayed and the conditions are satisfied.
When exiting the [MOTOR BRAKE CONTROL screen], the motor brakes of each
axis are locked when the servo is turned off.
When the servo is turned on, the motor brake is applied for the current axes.