7.8.2
Step Reset
Functional Explanation
Resets all execution conditions (excluding variables) for a current file and allows
execution of that program from the top.
This function is useful to set the repetitive counts in a variable and execute the
remaining counts.
Operating Procedure
Step 1: Selecting step reset
Press the [STEP] key.
Step 2: Execution of step reset
To reset, press the [EXE] key in succession. To cancel reset, press the [ESC] key.
Cautions
When you do not wish to execute the setting of initial conditions at the head of the
program, use the cycle reset instead.
7.8.3
Cycle Reset
Functional Explanation
Resets all execution conditions (excluding global variables) for a current file and allows
execution of the main program from the step indicated by label RCYCLE. This
function is useful when you do not wish to execute the setting of the initial condition.
Operating Procedure
Step 1: Selecting cycle reset
Press the [CYCLE] key.