STE 85412
2-6
TP3000 OPERATOR S MANUAL
series Robot Controller
Cautions
While the EMERGENCY stop switch is pressed, the servo power will not turn on.
Be sure to cancel an emergency stop before turning on the servo power.
The servo power can be turned on through the teach pendant only when the
TEACHING mode is selected.
The servo power does not turn on by an external control signal when the contacts
for the emergency stop and servo off external signals are open and when the
control panel teach pendant connector is disconnected.
The teach pendant connector (or dummy connector) should be connected to the
TP connector of the control panel. For more information, see the Interface
Manual.
Although the servo power can be turned on continuously up to the second servo
unit, a time interval must be set before turning on a third servo unit.
2.2.4
Turning OFF the Servo Power (TS3000)
Functional Explanation
Turns off the main circuit power of the servo driver. The servo-controlled axes are set
free and any brake is activated.
Operating Procedure
Step 1: Turning off the servo power.
Press the SERVO OFF switch on the control panel.
When the main circuit power of the servo driver has turned off, the SERVO OFF LED
equipped on the control panel is illuminated with the SERVO ON LED turned off. The
SERVO ON LED on the teach pendant also goes out.