STE 85412
7-12
TP3000
series Robot Controller
7.6
Startup [RUN]
Functional Explanation
Starts a test operation under the predetermined conditions. It is used for program
verification operation.
It is also used for resuming an operation after the stop.
Operating Procedure
Step 1: Setting of running conditions.
Set the conditions for executing the file selection, run mode selection speed override
setting.
Step 2: Servo ON
Lightly grip the Enable switch of the TP3000 teach pendant and open the contact of the
Safety switch. (When the Safety switched is lightly gripped, the TP3000's screen and
key sheet switch to the JOG key sheet.)
The servo turns on when the Servo ON switch on the TP3000's main body is pressed
when there is no error.
TP3000's Rear View
Servo ON switch
Enable switch