STE 85412
7-29
TP3000
series Robot Controller
Step 4: Changing a variable value [CHG REST]
Overwrite the program file values.
Position the cursor on a variable value, and press the [CHG REST] key.
(The value input procedure is the same as that in Step 3.)
Cautions
If the specified variable does not exist (has not been selected) in the program,
"------.---" is displayed.
Up to thirty (30) variable names can be registered.
If no program is being selected, displayed value may not be correct.
The [CHG+R] function cannot be executed for the global variable yet to be
initialized (such as position type array variable which is not taught the robot).
The position type data can be changed in the range of ±3 mm or ±3 deg.
7.11 Direct Execution [DO]
Functional Explanation
Directly executes a SCOL command by entering it through the teach pendant. This
function is used to establish the conditions leading to a specified step when you wish to
execute a program from midway. The global variables in the program cannot be used,
however.
Operating Procedure
Step 1: Calling the direct execution function
Press the [DO] key on the top key sheet in the TEACHING mode.