STE 85412
– 1-3 –
TP3000 OPERATOR’S MANUAL
series Robot Controller
1.2
Various Modes of Operation
External automatic
mode
(EXTERNAL)
Used to perform automatic programmed
operation by means of using external signals or
communication.
Master
mode
Internal automatic
mode
(INTERNAL)
Used to perform automatic programmed
operation through the control panel or teach
pendant.
* The TSL3000 does not have the internal
automatic operation function.
Teaching mode
(TEACHING)
Used to perform such operations as teaching,
guiding, file management and program test run,
using the teach pendant.
Use the mode selection key on the control panel to select the master mode.
Utility
(UTILITY)
Used to perform such operations as coordinate selection,
position monitor and signal monitor using the teach
pendant, irrespective of the master mode currently
selected.
Error display
(ERROR)
Used to display and reset an error using the teach pendant,
irrespective of the master mode currently selected.
The emergency stop and servo OFF operations are possible irrespective of the mode
currently selected.
Mode selection key
TS3000
TSL3000