STE 85412
12-4
TP3000
series Robot Controller
Operating Procedure
Step 1: Execution of error reset
Press the [RESET] key during error display. The display of errors that have been
resolved, fault signals and buzzer are reset.
Cautions
The soft limit and emergency stop are automatically reset after a relevant error
has been corrected.
If a reset operation is performed when the cause of the error has not been
removed, the error will occur again. In such a cause, the error generation time is
updated at the reset operation.
12.5 Error Reset by External Signal
Functional Explanation
Resets all the errors whose cause has been removed.
Operating Procedure
(a) Switch the master key and set the EXT.SIG mode.
(b) Reset the error by turning "ON" the ALARM_RST signal.
Cautions
This function can be executed, irrespective of presence or absence of the teach
pendant.