STE 85412
2-3
TP3000 OPERATOR S MANUAL
series Robot Controller
ALARM: Alarm number currently generated in the
controller.
If two (2) or more alarms have occurred,
such alarm numbers are displayed at
intervals of two (2) seconds.
When an alarm occurs, this switch flashes.
(7) UF1 & UF2 switches/LEDs
: User function switches.
This switch input can be referred to by DIN and the lamp
output by DOUT.
(8) EMERGENCY
: EMERGENCY stop pushbutton switch.
2.2.2
Turning ON the Main Power
!
CAUTION
If an abnormality occurs when the main power switch of the controller is turned on
or if the POWER LED lamp on the control panel remains off after the main power
switch of the controller is turned on, turn off the main power immediately and check
the wiring. Failure to do so can cause an electric shock or fire.
When the power is turned on, the controller enters a program reset status.
Functional Explanation
The controller is started up by the system programs saved in the flash memory.
Operating Procedure
Step 1: Turning on the main power.
Set the MAIN POWER switch on the controller to ON position, and the POWER LED
and SERVO OFF LED are illuminated.
The controller starts initializing the system. The STOP LED on the control panel is
illuminated and the system is ready for an operation with the initial display of a selected
mode called on the teach pendant.