Cautions
The RUN switch equipped on the control panel and "startup command" external
control signal are inoperative in the test operation mode.
To execute a program from the top, execute [RESET] and [PROG] followed by
[RUN].
7.7
Stop
7.7.1
CYCLE Stop
Functional Explanation
Selects "CYCLE" for the run mode and stops an automatic operation at the program
end. This function is used to stop the robot after the end of an operation.
Operating Procedure
Step 1: Selection of the [CYCLE] key
Press the [MODE] key. The [CONT], [CYCLE], [SEG] and [STEP] keys are displayed on
the keyboard.
Press the [CYCLE] key in succession.
Step 2: Entering the [EXE] key
Press the [EXE] key. When mode changing is executed, "CYCLE" is displayed in the M:
field on the status bar at the bottom of the screen. When executed up to the program
end, automatic operation stops.