Press the EMERGENCY stop pushbutton switch equipped on the control panel or teach
pendant, or use the "emergency stop" external control signal.
The servo power is turned off and the SERVO ON switch LED on the control panel
goes out and the SERVO OFF switch LED goes on.
The SERVO ON switch LED on the teach pendant goes out.
Cautions
All of the EMERGENCY stop switches on the control panel and teach pendant,
and "emergency stop" external control signal are operative.
At the time of an emergency, use whichever key you can get at quickest.
The EMERGENCY stop switches on the control panel and teach pendant are of a
lock type.
When pressed, they remain depressed and locked. To reset, turn and unlock the
switch.
While the EMERGENCY stop switch is ON, the servo power cannot be turned on.
7.8
Reset
Functional Explanation
Program reset, step reset, cycle reset, output signal reset and execution file reset can
be performed.
The resets other than the output signal reset cannot be performed unless a file is
selected.
Emergency Stop switch