STE 85412
9-4
TP3000 OPERATOR S MANUAL
series Robot Controller
Cautions
For the functions and use of the external control signals, see the Interface
Manual.
For the data communication function with the host computer, see the
Communication Manual.
In the external automatic mode, only the MODE select switch, STOP switch,
SERVO ON switch, SERVO OFF switch and EMERGENCY stop pushbutton
switch provided on the control panel are operative.
The mode can be changed through "USER. PAR".
"EX. 232C" and "EX. ETHER" are controlled by the host computer. Enter
[U00] to change over to either mode. For details, see the User Parameter
Manual.
9.2
Selecting File
Functional Explanation
Selects or resets an execution file.
Operating Procedure
Observe one of the following manners to select a file.
(a) File selection by automatic start file
Create an "automatic start file" having the name specified by a SELECT command in
the controller in advance, and then turn "ON" the power to the controller. For more
details on automatic start files, please see Section 4, "Program Editing".
(b) File selection by external signal
Specify a file to be selected externally in the user parameter beforehand. While the
external signal mode is selected, an execution file can be selected by the external
signal.
For the externally selected file and external signals, see the User Parameter Manual
and Interface Manual, respectively.
(c) File selection by internal automatic mode or test operation mode (TS3000)
Select in advance a file you wish to execute in the internal automatic mode or test
operation mode. Select the either mode by means of the MODE select switch on the
control panel.