Relief Valve (R1) and (R2) Pressure Test (Cutting (Mow) Circuit)
(5410/5410-G/5410-D/5510/5510-G/5510-D/5610)
g230023
Figure 93
The relief valve (R1) and (R2) pressure test should be performed to ensure that
the cutting unit circuit relief pressures are correct.
Note:
The front cutting unit circuit is protected by relief valve (R2). The rear
cutting unit circuit is protected by relief valve (R1); refer to
Diagrams (5410/5410-D/5510/5510-D/5610) (page 6–20)
.
Test Procedure
1. Ensure that the hydraulic fluid is at normal operating temperature by
operating the machine under load for approximately 10 minutes.
Hydraulic System: Testing the Hydraulic System
Page 6–74
Reelmaster
®
5410/5510/5610 Series
15216SL Rev C