Using the InfoCenter Display for Troubleshooting
g189681
Figure 214
1.
Diagnostics menu
4.
Menu/back button
2.
Left/right button
5.
Diagnostics items
3.
Down button
The diagnostics screen of the InfoCenter display can be very helpful when
troubleshooting machine operation issues (refer to
Diagnostics Screen (page
7–19)
). The diagnostics screen (
) lists a variety of machine operations
and the current state of the inputs, qualifiers, and outputs required to allow
the operation to proceed. The electrical components involved in the following
machine operations can be evaluated using the diagnostics screen prior to
testing each component individually:
•
Lift
The components necessary to raise the cutting units.
•
Lower
The components necessary to lower the cutting units.
•
PTO
The components necessary to engage the cutting units.
•
Engine
The components necessary to start and run the engine.
•
Backlap
The components necessary to engage the cutting units in the
reverse direction for backlapping.
If a machine operation is malfunctioning, the following procedure can help
identify the cause of the component or circuit wiring causing the malfunction.
1. Park the machine on a level surface, lower the cutting units, set the parking
brake, and shut off the engine.
2. Set the key switch to the O
N
position and navigate to the InfoCenter
Diagnostic Screen.
Electrical System: Troubleshooting
Page 7–28
Reelmaster
®
5410/5510/5610 Series
15216SL Rev C
Summary of Contents for Reelmaster 5510 Series
Page 4: ...NOTES NOTES Page 4 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Page 10: ...Preface Page 10 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Page 18: ...Safety Safety and Instructional Decals Page 1 8 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Page 356: ...Hydraulic System Service and Repairs Page 6 238 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Page 594: ...Cutting Unit Service and Repairs Page 9 64 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Page 662: ......