Gear Pump (P3) Flow Test (Using Tester with Flow Meter and
Pressure Gauge) (5410/5410-G/5410-D/5510/5510-G/5510-D/5610)
g230020
Figure 87
The gear pump (P3) flow test should be performed to ensure that the traction
charge circuit and steering circuit have adequate hydraulic flow.
Test Procedure
1. Park machine on a level surface with the cutting units lowered and
disengaged. Ensure that the engine is shut off. Apply the parking brake.
2. Read all Warning, Cautions, and precautions listed at the beginning of this
section.
Reelmaster
®
5410/5510/5610 Series
Page 6–65
Hydraulic System: Testing the Hydraulic System
15216SL Rev C