Testing the Engine Relays with 5 Terminals (continued)
g228831
Figure 261
Start relay
g228832
Figure 262
Power and fuel pump relay
3. Using a multimeter (ohms setting), measure coil resistance between
terminals 85 and 86 (
or
). Resistance should be as
listed in table below.
Relay
Coil Resistance
Start
81 to 99 ohms
Power or Fuel Pump
111 to 135 ohms
4. Connect multimeter (ohms setting) leads to relay terminals 30 and 87.
Ground terminal 86 and apply +12 VDC to terminal 85. The relay should
have continuity between terminals 30 and 87 as +12 VDC is applied to
terminal 85. The relay should not have continuity between terminals 30 and
87 as +12 VDC is removed from terminal 85.
5. Disconnect voltage from terminal 85 and multimeter lead from terminal 87.
Replace relay if testing determines that it is damaged.
6. Install relay into power center, install power center cover and lower hood
when relay testing is complete.
7. Connect multimeter (ohms setting) leads to relay terminals 30 and 87A.
Apply +12 VDC to terminal 85. The relay should not have continuity between
terminals 30 and 87A as +12 VDC is applied to terminal 85. The relay should
have continuity between terminals 30 and 87A as +12 VDC is removed from
terminal 85.
8. Disconnect voltage and multimeter leads from the relay terminals. Replace
relay if testing determines that it is damaged.
Reelmaster
®
5410/5510/5610 Series
Page 7–93
Electrical System: Testing the Electrical Components
15216SL Rev C
Summary of Contents for Reelmaster 5510 Series
Page 4: ...NOTES NOTES Page 4 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Page 10: ...Preface Page 10 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Page 18: ...Safety Safety and Instructional Decals Page 1 8 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Page 356: ...Hydraulic System Service and Repairs Page 6 238 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Page 594: ...Cutting Unit Service and Repairs Page 9 64 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Page 662: ......