Using Machine Faults (continued)
Machine Fault Table (continued)
Fault Code
Fault Description
Service Suggestions
9
Engine alternator charging is too
low
Check the alternator drive belt
Check the engine alternator and
circuit wiring
10
Engine has not been seen on
the CAN-bus for 10 seconds
(machines with Yanmar diesel or
Kubota gasoline engine)
Check CAN-bus connection to
engine ECU
Verify battery power exists at engine
ECU
Check CAN-bus terminator resistors
12
InfoCenter has not been seen on
the CAN-bus for 1 second
Check CAN-bus connection to
InfoCenter Display
Verify battery power exists at
InfoCenter Display
Check CAN-bus terminator resistors
13
Key switch is damaged
Check the switch and circuit wiring
15
Engine speed switch is damaged
(machines with Yanmar diesel or
Kubota gasoline engine)
Check the control arm engine speed
switch and circuit wiring
19
Engine coolant temperature
sensor circuit has open or short
Check the engine coolant sensor
and circuit wiring
24
Joystick raise and lower switches
closed at same time
Check the joystick switches and
circuit wiring
26
TEC output current to energize
start relay is excessive
Check the start relay and circuit
wiring
27
TEC output current to fuel pump
is excessive
Check the fuel pump and circuit
wiring
37
TEC output current to energize
glow relay is excessive
Check the glow relay and circuit
wiring
53
TEC output current for hydraulic
solenoid coil SV1 is excessive
Check the lift control manifold
solenoid coil SV1 and circuit wiring
54
TEC output current for hydraulic
solenoid coil SV2 is excessive
Check the lift control manifold
solenoid coil SV2 and circuit wiring
55
TEC output current for hydraulic
solenoid coil SV3 is excessive
Check the lift control manifold
solenoid coil SV3 and circuit wiring
56
TEC output current for hydraulic
solenoid coil SVRV is excessive
Check the lift control manifold
solenoid coil SVRV and circuit
wiring
57
TEC output current for hydraulic
solenoid coil MSV1 is excessive
Check the mow control manifold
solenoid coil MSV1 and circuit wiring
58
TEC output current for hydraulic
solenoid coil MSV2 is excessive
Check the mow control manifold
solenoid coil MSV2 and circuit wiring
68
Alternator not charging
Check the engine alternator and
circuit wiring
69
Low engine oil pressure
Check the engine oil pressure
switch and circuit wiring
Electrical System: Troubleshooting
Page 7–34
Reelmaster
®
5410/5510/5610 Series
15216SL Rev C
Summary of Contents for Reelmaster 5510 Series
Page 4: ...NOTES NOTES Page 4 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Page 10: ...Preface Page 10 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Page 18: ...Safety Safety and Instructional Decals Page 1 8 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Page 356: ...Hydraulic System Service and Repairs Page 6 238 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Page 594: ...Cutting Unit Service and Repairs Page 9 64 Reelmaster 5410 5510 5610 Series 15216SL Rev C...
Page 662: ......