Description
Reset
Type
Name
Bit/Field
SS0 FIFO Overflow
Description
Value
The FIFO has not overflowed.
0
The FIFO for Sample Sequencer 0 has hit an overflow condition,
meaning that the FIFO is full and a write was requested. When
an overflow is detected, the most recent write is dropped.
1
This bit is cleared by writing a 1.
0
RW1C
OV0
0
June 18, 2014
1090
Texas Instruments-Production Data
Analog-to-Digital Converter (ADC)