Description
Reset
Type
Name
Bit/Field
MnPWM3
Enable Update Mode
Description
Value
Immediate
Writes to the
PWM3EN
bit in the
PWMENABLE
register are used
by the PWM generator immediately.
0x0
Reserved
0x1
Locally Synchronized
Writes to the
PWM3EN
bit in the
PWMENABLE
register are used
by the PWM generator the next time the counter is 0.
0x2
Globally Synchronized
Writes to the
PWM3EN
bit in the
PWMENABLE
register are used
by the PWM generator the next time the counter is 0 after a
synchronous update has been requested through the PWM
Master Control (
PWMCTL
) register.
0x3
0
RW
ENUPD3
7:6
MnPWM2
Enable Update Mode
Description
Value
Immediate
Writes to the
PWM2EN
bit in the
PWMENABLE
register are used
by the PWM generator immediately.
0x0
Reserved
0x1
Locally Synchronized
Writes to the
PWM2EN
bit in the
PWMENABLE
register are used
by the PWM generator the next time the counter is 0.
0x2
Globally Synchronized
Writes to the
PWM2EN
bit in the
PWMENABLE
register are used
by the PWM generator the next time the counter is 0 after a
synchronous update has been requested through the PWM
Master Control (
PWMCTL
) register.
0x3
0
RW
ENUPD2
5:4
MnPWM1
Enable Update Mode
Description
Value
Immediate
Writes to the
PWM1EN
bit in the
PWMENABLE
register are used
by the PWM generator immediately.
0x0
Reserved
0x1
Locally Synchronized
Writes to the
PWM1EN
bit in the
PWMENABLE
register are used
by the PWM generator the next time the counter is 0.
0x2
Globally Synchronized
Writes to the
PWM1EN
bit in the
PWMENABLE
register are used
by the PWM generator the next time the counter is 0 after a
synchronous update has been requested through the PWM
Master Control (
PWMCTL
) register.
0x3
0
RW
ENUPD1
3:2
June 18, 2014
1706
Texas Instruments-Production Data
Pulse Width Modulator (PWM)