Register 104: CRC Module Run Mode Clock Gating Control (RCGCCCM), offset
0x674
The
RCGCCCM
register provides software the capability to enable and disable the CRC in Run
mode. When enabled, the module is provided a clock and accesses to module registers are allowed.
When disabled, the clock is disabled to save power and accesses to module registers generate a
bus fault.
Important:
This register should be used to control the clocking for the CRC module.
CRC Module Run Mode Clock Gating Control (RCGCCCM)
Base 0x400F.E000
Offset 0x674
Type RW, reset 0x0000.0000
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
reserved
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Type
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Reset
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
R0
reserved
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Type
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Reset
Description
Reset
Type
Name
Bit/Field
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0
RO
reserved
31:1
CRC Run Mode Clock Gating Control
Description
Value
The CRC5 module is disabled.
0
Enable and provide a clock to the CRC module in Run mode.
1
0
RW
R0
0
401
June 18, 2014
Texas Instruments-Production Data
Tiva
™