![Texas Instruments TM4C1294NCPDT Datasheet Download Page 969](http://html1.mh-extra.com/html/texas-instruments/tm4c1294ncpdt/tm4c1294ncpdt_datasheet_1095593969.webp)
Figure 13-8. Timer Daisy Chain
GP Timer N
Timer B
Timer A
1
0
GP Timer N+1
Timer B
Timer A
1
0
GPTMTnMR.TnWOT
Timer B ADC Trigger
Timer A ADC Trigger
Timer B ADC Trigger
Timer A ADC Trigger
GPTMTnMR.TnWOT
13.3.5
Synchronizing GP Timer Blocks
The
GPTM Synchronizer Control (GPTMSYNC)
register in the GPTM0 block can be used to
synchronize selected timers to begin counting at the same time. Setting a bit in the
GPTMSYNC
register causes the associated timer to perform the actions of a timeout event. An interrupt is not
generated when the timers are synchronized. If a timer is being used in concatenated mode, only
the bit for Timer A must be set in the
GPTMSYNC
register.
Note:
All timers must use the same clock source for this feature to work correctly.
Table 13-10 on page 969 shows the actions for the timeout event performed when the timers are
synchronized in the various timer modes.
Table 13-10. Timeout Actions for GPTM Modes
Time Out Action
Count Dir
Mode
N/A
─
32-bit One-Shot
(concatenated timers)
Count value = ILR
Down
32-bit Periodic
(concatenated timers)
Count value = 0
Up
Count value = 0
Up
32-bit RTC
(concatenated timers)
N/A
─
16- bit One Shot
(individual/split timers)
Count value = ILR
Down
16-bit Periodic
(individual/split timers)
Count value = 0
Up
Count value = ILR
Down
16-bit Edge-Count
(individual/split timers)
Count value = 0
Up
Count value = ILR
Down
16- bit Edge-Time
(individual/split timers)
Count value = 0
Up
Count value = ILR
Down
16-bit PWM
969
June 18, 2014
Texas Instruments-Production Data
Tiva
™