Description
Reset
Type
Name
Bit/Field
Interrupt Enable
Description
Value
Interrupt generation is disabled. Software can use the
COUNT
bit to determine if the counter has ever reached 0.
0
An interrupt is generated to the NVIC when SysTick counts
to 0.
1
0
RW
INTEN
1
Enable
Description
Value
The counter is disabled.
0
Enables SysTick to operate in a multi-shot way. That is, the
counter loads the
RELOAD
value and begins counting down.
On reaching 0, the
COUNT
bit is set and an interrupt is
generated if enabled by
INTEN
. The counter then loads the
RELOAD
value again and begins counting.
1
0
RW
ENABLE
0
151
June 18, 2014
Texas Instruments-Production Data
Tiva
™
TM4C1294NCPDT Microcontroller