Automated Functions
X
TRA
Operator’s Manual
20077/021 US
7-5
automatically,” and the Last Bowl function is terminated.
If the volume of RBCs is sufficient to start a Concentrate cycle automatically but not to complete
filling the bowl, the system alerts the operator with the message, “RBC bag empty. Bowl not
filled”. In this case, the operator can decide to either process a partial bowl (with normal or
double saline solution volume) or to discard the residual volume in the bowl.
• At the end of the Concentrate phase, the Wash phase is activated automatically without any
intervention required by the operator.
• At the end of the Wash phase or at the end of the Fat Removal phase (if the Pfat protocol is in
use), the Empty phase is automatically initiated. Once the bowl is empty, the Empty phase
continues to empty the Empty line without any intervention required by the operator. The Last
Bowl function is then complete and deactivated.
While the Last Bowl function is active, the Last Bowl symbol is displayed in the status area.
The Last Bowl function may be interrupted in the following ways:
• By pushing the Stop button.
• By activating the Emergency function.
• By switching to the Manual operating mode.
CAUTION
The Concentration function reprocesses already collected red blood cells
subjecting them again to the mechanical action of the pump and the
centrifuge. The repeated use of the Concentration function on the same red
blood cells might lead to them being damaged and therefore to their loss.
WARNING
WARNING
WARNING
WARNING
Summary of Contents for 75220
Page 1: ...Operator s Manual SOFTWARE VERSION 2 00 20077 021 US FOR US MARKET ONLY...
Page 70: ...System Description 3 32 20077 021 US XTRA Operator s Manual...
Page 148: ...Special Cycles 6 10 20077 021 US XTRA Operator s Manual...
Page 156: ...Automated Functions 7 8 20077 021 US XTRA Operator s Manual...
Page 178: ...Programmability Option 9 10 20077 021 US XTRA Operator s Manual...
Page 206: ...Preoperative Sequestration PPP and PRP 10 28 20077 021 US XTRA Operator s Manual...
Page 232: ...Vacuum Module 13 10 20077 021 US XTRA Operator s Manual...
Page 260: ...Troubleshooting 14 28 20077 021 US XTRA Operator s Manual...
Page 270: ...Maintenance 15 10 20077 021 US XTRA Operator s Manual...
Page 282: ...A 6 20077 021 US XTRA Operator s Manual...
Page 284: ...B 2 20077 021 US XTRA Operator s Manual...
Page 286: ...C 2 20077 021 US XTRA Operator s Manual...
Page 298: ...D 2 20077 021 US XTRA Operator s Manual...