Appendix
B-30
2852 AR: Close command after 1pole, 1st
cycle (AR Close1.Cyc1p)
Automatic
Reclosure
OUT
*
*
LED
BO
40
152 1
2853 AR: Close command after 3pole, 1st
cycle (AR Close1.Cyc3p)
Automatic
Reclosure
OUT
*
*
LED
BO
40
153 1
2854 AR: Close command 2nd cycle (and
higher) (AR Close 2.Cyc)
Automatic
Reclosure
OUT
*
*
LED
BO
128 129 1
2861 AR: Reclaim time is running (AR T-
Recl. run.)
Automatic
Reclosure
OUT
*
*
LED
BO
40
161 1
2862 AR successful (AR successful)
Automatic
Reclosure
OUT
*
*
LED
BO
40
162 1
2863 Definitive TRIP (Definitive Trip)
Automatic
Reclosure
OUT
*
*
LED
BO
40
163 1
GI
2864 AR: 1pole trip permitted by internal
AR (AR 1p Trip Perm)
Automatic
Reclosure
OUT
*
*
LED
BO
40
164 1
GI
2865 AR: Synchro-check request (AR
Sync.Request)
Automatic
Reclosure
OUT
*
*
LED
BO
40
165 2
GI
2871 AR: TRIP command 3pole (AR TRIP
3pole)
Automatic
Reclosure
OUT
*
ON
LED
BO
40
171 2
GI
2889 AR 1st cycle zone extension release
(AR 1.CycZoneRel)
Automatic
Reclosure
OUT
*
*
LED
BO
40
160 1
2890 AR 2nd cycle zone extension release
(AR 2.CycZoneRel)
Automatic
Reclosure
OUT
*
*
LED
BO
40
169 1
2891 AR 3rd cycle zone extension release
(AR 3.CycZoneRel)
Automatic
Reclosure
OUT
*
*
LED
BO
40
170 1
2892 AR 4th cycle zone extension release
(AR 4.CycZoneRel)
Automatic
Reclosure
OUT
*
*
LED
BO
40
172 1
2893 AR zone extension (general) (AR
Zone Release)
Automatic
Reclosure
OUT
*
*
LED
BO
40
173 1
GI
2894 AR Remote close signal received
(AR Remote Close)
Automatic
Reclosure
OUT
*
ON
LED
BO
40
129 1
2895 No. of 1st AR-cycle CLOSE com-
mands,1pole (AR #Close1./1p=)
Statistics
OUT
2896 No. of 1st AR-cycle CLOSE com-
mands,3pole (AR #Close1./3p=)
Statistics
OUT
2897 No. of higher AR-cycle CLOSE com-
mands,1p (AR #Close2./1p=)
Statistics
OUT
2898 No. of higher AR-cycle CLOSE com-
mands,3p (AR #Close2./3p=)
Statistics
OUT
2901 >Switch on synchro-check function
(>Sync. on)
Synchronism
and Voltage
Check
SP
*
*
LED BI
BO
2902 >Switch off synchro-check function
(>Sync. off)
Synchronism
and Voltage
Check
SP
*
*
LED BI
BO
2903 >BLOCK synchro-check function
(>BLOCK Sync.)
Synchronism
and Voltage
Check
SP
*
*
LED BI
BO
F.No.
Description
Function
Type of Infor-
mation
Log-Buffers
Configurable in Matrix
IEC 60870-5-103
E
v
e
n
t L
o
g
On
/Off
T
rip
(
F
au
lt
) L
o
g
O
n
/O
ff
G
ro
und
Fa
ul
t L
og O
n
/O
ff
Ma
rk
ed
in
Os
cill
. Rec
o
rd
LE
D
B
ina
ry
In
pu
t
Fu
nc
ti
o
n
K
e
y
B
ina
ry
Ou
tp
ut
Ev
e
n
t L
o
g
Ty
p
e
In
fo
rm
at
io
n
-No
Da
ta
Un
it
(
A
SDU)
Ge
n
e
ra
l In
te
rr
o
g
at
io
n
Summary of Contents for siprotec 7SA522
Page 20: ...7SA522 Manual C53000 G1176 C119 2 ...
Page 64: ...7SA522 Manual C53000 G1176 C119 2 ...
Page 89: ...SIPROTEC 4 Devices 4 25 7SA522 Manual C53000 G1176 C119 2 Figure 4 20 CFC Logic example ...
Page 408: ...7SA522 Manual C53000 G1176 C119 2 ...
Page 456: ...7SA522 Manual C53000 G1176 C119 2 ...
Page 516: ...7SA522 Manual C53000 G1176 C119 2 ...
Page 620: ...Appendix B 48 ...