Chapter 3
Device Management
RUGGEDCOM ROX II
User Guide
168
Configuring a Frame Relay Connection
Section 3.24.13
Configuring a Frame Relay Connection
To configure a frame relay connection for a T1 or E1 line, do the following:
1. Change the mode to
Edit Private
or
Edit Exclusive
.
2. Depending on the WAN module, navigate to either:
•
For T1/E1 Lines
interface
»
wan
»
{interface}
»
{protocol}
»
channel
»
{number}
»
connection
, where
{interface}
is the
WAN interface,
{parameter}
is either T1 or E1, and
{number}
is the channel number.
•
For DDS
interface
»
wan
»
{interface}
»
dds
»
connection
, where
{interface}
is the WAN interface,
{parameter}
is
either T1 or E1, and
{number}
is the channel number.
3. Click the
+
symbol in the menu next to
framerelay
. The
Frame Relay Parameters
form appears.
1
2
3
4
5
Figure 177: Frame Relay Parameters Form – Switch Selected
1.
Station List
2.
Signal List
3.
T391 Box
4.
N391 Box
5.
N392 Box
6.
N393 Box