Remote Control Commands
R&S
®
SGU100A
187
User Manual 1176.7726.02 ─ 09
Example:
SYSTem:COMMunicate:NETWork:IPADdress:MODE AUTO
The IP address is assigned automatically (DHCP)
Manual operation:
See
:SYSTem:COMMunicate:NETWork:MACaddress
<MacAddress>
Queries the MAC address of the network adapter.
Parameters:
<MacAddress>
string
Example:
SYST:COMM:NETW:MAC
queries the MAC address.
:SYSTem:COMMunicate:NETWork:RESTart
Restarts the network connection to the instrument, terminates the connection and sets
it up again.
Example:
SYSTem:COMMunicate:NETWork:RESTart
Usage:
Event
:SYSTem:COMMunicate:NETWork:STATus?
Queries the network configuration state.
Return values:
<State>
0 | 1 | OFF | ON
Usage:
Query only
:SYSTem:COMMunicate:NETWork[:COMMon]:HOSTname
<Hostname>
Sets the individual host name of the R&S
SGU.
Note:
it is recommended that you do not change the host name in order to avoid prob-
lems with the networdk connection. However, if you change the host name be sure to
use an unique name.
The host name is a protected parameter, To change it, first disable protection level 1
with command
Parameters:
<Hostname>
string
Example:
SYSTem:PROTect1:STATe OFF,123456
SYSTem:COMMunicate:NETWork:HOSTname 'SIGGEN'
sets the individual computer name of the R&S
SGU.
Manual operation:
See
SYSTem Subsystem