Remote control commands
R&S
®
NRX
378
User Manual 1178.5566.02 ─ 09
SOURce[:RF]:FREQuency[:VALue]
<freq>
Requires the sensor check source (R&S NRX-B1)
Sets the frequency of the output signal.
Parameters:
<freq>
Range:
50.0e6 to 1.0e9
*RST:
50.0e6
Default unit: Hz
Manual operation:
See
13.10
Configuring the analog signal ouput and the trigger
input/output
Configures the two multifunctional BNC connectors at the rear of the R&S NRX.
Further Information:
●
●
INPut<undef>:TRIGger:IMPedance
..................................................................................378
............................................................................................. 379
OUTPut:RECorder<output>:FEED:INDex
......................................................................... 380
OUTPut:RECorder<output>:LIMit:LOWer:CCDF
................................................................381
OUTPut:RECorder<output>:LIMit:LOWer[:VALue]
............................................................. 381
OUTPut:RECorder<output>:LIMit:LOWer:POWer
.............................................................. 381
OUTPut:RECorder<output>:LIMit:LOWer:RATio:RCOefficient
.............................................382
OUTPut:RECorder<output>:LIMit:LOWer:RATio:RFRatio
................................................... 382
OUTPut:RECorder<output>:LIMit:LOWer:RATio:RLOSs
.....................................................382
OUTPut:RECorder<output>:LIMit:LOWer:RATio:SWR
....................................................... 383
OUTPut:RECorder<output>:LIMit:LOWer:RATio[:VALue]
....................................................383
OUTPut:RECorder<output>:LIMit:UPPer:CCDF
................................................................ 384
OUTPut:RECorder<output>:LIMit:UPPer[:VALue]
..............................................................384
OUTPut:RECorder<output>:LIMit:UPPer:POWer
...............................................................384
OUTPut:RECorder<output>:LIMit:UPPer:RATio:RCOefficient
............................................. 385
OUTPut:RECorder<output>:LIMit:UPPer:RATio:RFRatio
....................................................385
OUTPut:RECorder<output>:LIMit:UPPer:RATio:RLOSs
..................................................... 386
OUTPut:RECorder<output>:LIMit:UPPer:RATio:SWR
........................................................ 386
OUTPut:RECorder<output>:LIMit:UPPer:RATio[:VALue]
.................................................... 386
..............................................................................................387
INPut<undef>:TRIGger:IMPedance
<impedance>
TIN
is set.
Configuring the analog signal ouput and the trigger input/output