SYSTem:TZONe
<hour>, <minute>
Sets the offset of the local time to the UTC time, due to the time zone. There can be an
additional offset due to daylight saving time (DST).
Parameters:
<hour>
Range:
-12 to 15
<minute>
Range:
-59 to 59
13.14.9
Notifications and errors
The R&S NRX handles events and errors in 2
different queues, depending on their
context:
●
SYSTem:SERRor
commands
●
SCPI communication error queue
SYSTem:ERRor
commands
In the following, the expressions "error number" and "error code" are used synony-
mously.
13.14.9.1
System event queue
This system list contains notices, warnings and static errors that happen in setup.
A static error remains in the queue until you solve it. It prevents the execution of nor-
mal measurements. For example, if a power sensor overload occurs, you need to
lower the input power to the power sensor. When you have done that, the static error
disappears.
Warnings and static errors, you can remove from the queue using
.
Chapter 15.2.1, "Interpreting notifications and their num-
Currently, the event type is not included in the description of the event.
.................................................................................................415
..............................................................................................416
SYSTem:SERRor[:ALL]?
Queries all events from the system event queue.
Returns a comma-separated list of unique event numbers.
Usage:
Query only
System information and configuration