![Rohde & Schwarz 1424.7805K02 User Manual Download Page 348](http://html1.mh-extra.com/html/rohde-and-schwarz/1424-7805k02/1424-7805k02_user-manual_1477791348.webp)
Remote control commands
R&S
®
NRX
348
User Manual 1178.5566.02 ─ 09
CALCulate<Measurement>[:CHANnel<Channel>][:POWer]:VBWidth:ENUM
<value>
Requires a wideband power sensor.
Sets the video filter bandwidth. Reducing the video bandwidth also increases the trig-
ger sensitivity.
Suffix:
<Measurement>
.
1 to 8
Measurement
<Channel>
1 to 2
1 = forward, 2 = reflection (reverse)
Parameters:
<value>
EFULl | E5M | E1M5 | E0M3
EFULl
Full
E5M
5
MHz
E1M5
1.5
MHz
E0M3
300
kHz
*RST:
EFULl
Manual operation:
See
13.8.5
Sensor ranges
Further information:
●
CALCulate<Measurement>[:CHANnel<Channel>]:INPut:ATTenuation:AUTO
CALCulate<Measurement>[:CHANnel<Channel>]:INPut:ATTenuation[:VALue]
CALCulate<Measurement>[:CHANnel<Channel>][:POWer][:AVG]:RANGe:AUTO
CALCulate<Measurement>[:CHANnel<Channel>][:POWer][:AVG]:RANGe:CLEVel:STATe
CALCulate<Measurement>[:CHANnel<Channel>][:POWer][:AVG]:RANGe:CLEVel[:VALue]
CALCulate<Measurement>[:CHANnel<Channel>][:POWer][:AVG]:RANGe[:VALue]
CALCulate<Measurement>[:CHANnel<Channel>]:INPut:ATTenuation:AUTO
<auto>
Requires an R&S
frequency selective power sensor.
Enables or disables the automatic setting of the input attenuation.
Suffix:
<Measurement>
.
1 to 8
Measurement
Configuring sensors