Chapter 2 Installation and Confirmation
14
2
1-2-2 Three-Phase 400V Series
Model name
(RM6F5-
□□□□
)
4001 4002 4003 4005 4007 4010 4015 4020
Maximum applicable
motor (HP / kW)
1/0.75 2/1.5 3/2.2 5/3.7 7.5/5.5 10/7.5 15/11 20/15
Rated output capability
(kVA)
1.9
2.7
3.7
6.1
8.4
13
17
23
Rated output current (A)
2.5
3.5
4.8
8
11
17
22
30
Rated output voltage (V)
Three-phase 380~480V
Range of output
frequency (Hz)
0.1~120.00Hz
Power source (
ψ
, V, Hz)
Three-phase 380~480V 50/60Hz
Input current (A)
3
4.2
5.8
9.6
13
20
25
38
Permissible AC power
source fluctuation
332~528V 50/60Hz / ±5
%
Overload protection
120% of drive rated output current for 1 min.
Cooling method
Nature cooling
Fan cooling
Applicable safety
standards
-
Protective structure
IP20, UL open type
IP20
Weight / Mass(kg)
1.8
1.8
1.9
2
2
5.3
5.4
5.6
Model name
(RM6F5-
□□□□
)
4025 4030 4040 4050 4060 4075 4100 4125
Maximum applicable
motor (HP / kW)
25/18.5 30/22 40/30 50/37 60/45 75/55 100/75 125/90
Rated output capability
(kVA)
28
34
43
56
66
82
105
134
Rated output current (A)
37
45
56
73
87
108
138
176
Rated output voltage (V)
Three-phase 380~480V
Range of output
frequency (Hz)
0.1~400.00Hz
Power source (
ψ
, V, Hz)
Three-phase 380~480V 50/60Hz
Input current (A)
42
52
64
84
100
130
155
177
Permissible AC power
source fluctuation
332~528V 50/60Hz / ±5
%
Overload protection
120% of drive rated output current for 1 min.
Cooling method
Fan cooling
Applicable safety
standards
-
Protective structure
IP20
IP00 (IP20
OPTION)
Weight / Mass(kg)
5.7
5.8
16
16
17
18
44
45