Vin Bias
Bias -1.00~1.00
F_128
Iin Bias
a.( General Mode)
The corresponding frequency command value of analog command (C.V) =
Maximum output freq. (F_017) x Analog input bias (F_041 or F_128)
EX: If analog input gain (F_040 or F_127) = 1.00
Maximum output frequency =60.0Hz Maximum output frequency =60.0Hz
Analog input bias=0.05 Analog input bias=-0.05
Example of reverse control application:
Analog
Command
60.0Hz
60.0Hz
3.0Hz
-3.0Hz
0V(4mA)
0V(4mA)
0.5V(4.8mA)
10V(20mA)
Output
Frequency
Analog
Command
Output
Frequency
Bias=1
Bias=0.05
Bias=-0.05
Bias=1
10V(20mA)
Max. output freq.=60.0Hz
Analog input gain=0.00
Analog input bias=1.00
Analog
command
0V(4mA)
10V(20mA)
60.0Hz
0Hz
Frequency
command
b.
(F_103≠0)
The corresponding PV value of Iin analog input bais =
Maximum transducer (F_007) x Analog input bias (F_128)
command
analog
of
v alue
command
f requency
ing
correspond
The
C.V
*
C.V
command)
(Analog
20mA)
(or
10V
C.V)
-
command
f req.
(Max.
command
Freq.