Chapter 8 Communication Description
136
8
●
Registers
– Read Operation
Reg. No.
Name
Description
2100H
Drive error code
00H No error
01H Drive over current (OC)
02H Over voltage (OE)
03H Drive overheat (OH)
04H Drive overload (OL1)(OL2)
05H Motor overload (OL)
06H External fault (EF)
07H Short protection (SC)
08H A/D converter error (AdEr)
09H-
12H
Reserved
13H Grounding fault (GF)
14H Under voltage during operation (LE1)
15H EEPROM error (EEr)
16H Reserved
17H Drive output interruption (bb)
18H System overload (OLO)
19~20 Reserved
21
Coast to stop (Fr)
22H-
30H
Reserved
31H PID feedback signal error.
32H Water shortage protection(noFB)
33H Over pressure protection(OP)
2101H
Drive status 1
b0~b7 Reserved
b8
1: Frequency control by communication
b9
1: Frequency control by analog inputs
bA
1: Operation command by communication
bB
1: Parameter locking
bC
1: Drive running status
bD
1: Jog running status
bE
1: Forward indication
bF
1: Reverse indication
2102H
Frequency command
Monitor drive’s frequency command (unit: 0.01Hz)
2103H
Output frequency
Monitor drive’s output frequency(unit: 0.01Hz)
2104H
Output current
Monitor drive’s output current(unit: 0.1A)
2105H
DC bus voltage
Monitor drive’s DC bus voltage(unit: 0.1V)
2106H
Output voltage
Monitor drive’s AC output voltage(unit: 0.1V)
2107H
Frequency of
multi-speed
Monitor drive’s frequency of multi-speed
*Note 2
2108H
PV value
Monitor drive’s PV value (unit: 0.1 bar)
2109H
Reserved
210AH
Reserved
210BH
Reserved
210CH
Reserved