AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 328 of 485
Command Syntax
[SOURce:]PULSe:WAVEFORM# <nr1 >
Description
This command sets the selected waveform using the wavefrom
number.
Parameters
Waveform number
Parameter Format
<nr1>, <cr>
Example
PULS:WAVEFORM 1
Query Format
[SOURce:]PULSe:WAVEFORM#?
Returned Data Format
<nr1>
Query Example
PULS:WAVEFORM#?
1.0000
Query Syntax
[SOURce:]PULSe:WAVEFORM#:MINimum?
Description
This command returns the minimum permissible set value for the
PULSE waveform.
Returned Data Format
<nr1>
Query Example
PULS:WAVEFORM#:MIN?
1
Query Syntax
[SOURce:]PULSe:WAVEFORM#:MAXimum?
Description
This command returns the maximum permissible set value for the
PULSE waveform.
Returned Data Format
<nr1>
Query Example
PULS:WAVEFORM#:MAX?
200
Query Syntax
[SOURce:]PULSe:WAVEFORM:DEFault?
Description
This command returns the default set value for the PULSE waveform.
Returned Data Format
<nr1>
Query Example
PULS:WAVEFORM:DEF?
1
Command Syntax
[SOURce:]PULSe:PHASe# < nr2 >, <cr>
Description
This command sets the initial PULSE phase angle for selected phase #
number. Only phase 2 (B) and 3 (C) are allowed.
Parameters
Phase No., < NORmal | SATurate >
Default is NORmal if optional second parameter is omitted.
Parameter Format
<nr1>, <cr>
Example
PULS:PHAS1 245.0
Query Format
[SOURce:]PULSe:PHASe#?
Returned Data Format
<nr1>, <cr>
Query Example
PULS:PHAS1?
245.0000
Summary of Contents for AFX Series
Page 484: ......