SECTION 5: UNPACKING AND INSTALLATION
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 88 of 485
5.18.5
RS232 Serial Interface
5.18.5.1
RS232 Interface and Remote Inhibit Function
On AFX Series models with firmware revision numbers lower than 2.0.13, there is a conflict
between the RS232 interface and the Remote Inhibit function. Both cannot be used at the
same time. To enable the Remote Inhibit input control line, the RS232 interface must be
disabled. This can be done using the browser interface over LAN or USB or from the front
panel. If the Remote Inhibit function is needed, use the USB interface instead of RS232.
To disable RS232 from Web browser, select
SYSTEM
Menu ->
INTERFACE SETUP
and move
the SERIAL CONFIGURATION ENABLE position
to OFF.
To disable RS232 form the front panel, press
the CONFIGURATION key to the left of the LCD, select Interfaces, then select RS232
Interface and set the Status field to
Disabled
. Refer to section 6.8.5.4 on page 173.
Note:
For units with firmware revision 2.0.13 or higher, the RS232 interface is
automatically disabled when enabling Remote Inhibit.
5.18.5.2
“A” and AG” Versions
The RS232 serial interface on “A” or “AG” versions of the AFX Series is incorporated in the
DB25 Auxiliary I/O connector located on the rear panel. Refer to section 4.14, “Auxiliary
PIN
Abbreviation
Description
Pin 1
RXD
RS232 I/F – Receive Data
Pin 2
TXD
Gnd
Pin 14
DTR
RS232 I/F – Transmit Data
Table 5-5: RS232 DB25 Tx and Rx Pin Locations
If only the RS232 interface function is used, a regular straight through DB9 to DB9 cable can
be used to connect to a PC serial port.