AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 344 of 485
SYSTem:INTERFace:PRESET:POWer:LIMit:SK#?
Apparent Power Limit
SYSTem:INTERFace:PRESET:KVA:LIMit <REQ: MIN|MAX|DEF|Value, OPT: MIN|MAX|DEF|Value, OPT:
MIN|MAX|DEF|Value, OPT: MIN|MAX|DEF|Value, OPT: MIN|MAX|DEF|Value>
SYSTem:INTERFace:PRESET:KVA:LIMit? <OPT: ALL|DEF> <OPT: ALL|DEF>
SYSTem:INTERFace:PRESET:KVA:LIMit:SK# <REQ: MIN|MAX|DEF|Value>
SYSTem:INTERFace:PRESET:KVA:LIMit:SK#?
Examples of programming User Preset Soft keys:
SYST:INTERF:PRESET:VOLT:AC 115.000,230.000,300.000,MAX
SYST:INTERF:PRESET:VOLT:DC MAX,200.000,0.000,-200.000,MIN
SYST:INTERF:PRESET:FREQ 50.000,60.000,400.000,800.000,1200.000
SYST:INTERF:PRESET:PHAS 0.000,90.000,120.000,180.000,240.000
SYST:INTERF:PRESET:CURR:LIM MAX,15.000,5.000
SYST:INTERF:PRESET:POW:LIM MAX,4.000,2.000,1.000
SYST:INTERF:PRESET:KVA:LIM MAX,4.000,2.000,1.000
Examples of programming a specific User Preset Soft key:
SYST:INTERF:PRESET:VOLT:AC:SK1 115
Examples of querying programming User Preset Soft key settings:
SYSTem:INTERF:PRESET:VOLT:AC?
-> 115.000,230.000,300.000,MAX
SYSTem:INTERF:PRESET:VOLT:DC?
-> MAX,200.000,0.000,-200.000,MIN
SYSTem:INTERF:PRESET:FREQ?
-> 50.000,60.000,400.000,800.000,1200.000
SYSTem:INTERF:PRESET:PHAS?
-> 0.000,90.000,120.000,180.000,240.000
SYSTem:INTERF:PRESET:CURR:LIM?
-> MAX,15.000,5.000
SYSTem:INTERF:PRESET:POW:LIM?
-> MAX,4.000,2.000,1.000
SYSTem:INTERF:PRESET:KVA:LIM?
-> MAX,4.000,2.000,1.000
Example of querying programming User Preset for a specific soft key number:
SYST:INTERF:PRESET:VOLT:AC:SK1?
-> 115.000