AFX SERIES® OPERATION MANUAL
Rear Panel, Connectors and Protection
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 188 of 485
7.2.1
External Voltage Sense Connector Rating and Isolation
Maximum rated voltage:
400V rms AC, 425Vdc
Maximum Current Rating:
1A
Connector Type:
AFX L Version
: Phoenix Contact P/N DFK-MSTBA
2,5 / 6-GF-5,08 – 1899029. Mating connector
provided in ship kit is P/N FKC 2,5 / 6-STF-5,08 -
1873249
AFX A Version
: Phoenix Contact P/N SPT 5 / 6-H-
7,5-ZB - 1719231
Designated Use:
AC or DC Load Connection
Isolation Rating:
600V
Wire Stripping Length:
10 mm
7.2.2
Load Connection without External Voltage Sense
AFX Series® power sources can be operated with internal voltage sense. For higher current
loads, the voltage at the load will drop due to the load cable impedance. Using the proper
wire gauge for the rated current of the AC source is required to minimize load cable
impedance.
7.2.3
Load Connection with External Voltage Sense.
The following points must be considered, when existing sense cables are connected directly
to the load or to the central load distribution point:
1.
Minimize the distance between the AC power source and the load as much as
possible to keep load wire length to a minimum.
2.
Directly connect
A, B, C
and
N
with
correct phasing
to the load distribution point
3.
Twist each phase sense wire with a neutral sense wire to minimize cross talk. Three
neutral connection points are provided for this purpose.
4.
Avoid overload of power wires
Summary of Contents for AFX Series
Page 484: ......