AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 362 of 485
8.9.13
Miscellaneous System Commands
Command Syntax
SYSTem:BEEP
Description
This command generates a beep from the front panel speaker. May
be used in ATE programs to get operator’s attention. Make sure the
beep volume is not set to 0. See
SYSTem:INTERFace:VOLume
cmd.
Returned Data Format
<cr>,…,<cr>
Query Format
None
Query Format
SYSTem:MEMory:CATalog?
Description
This command returns the available memory types catalog.
Returned Data Format
<cr>,…,<cr>
Query Example
SYST:MEM:CAT?
INTERNAL, RAM
Command Syntax
SYSTem:MEMory:REMove
Description
This command unmounts system memory.
Returned Data Format
<cr>,…,<cr>
Query Format
None
Command Syntax
SYSTem:DELete <PATH>
Description
This command deletes a file or folder. The path or filename can be
between double quotation marks or not.
Parameters
PATH or FILE
Parameter Format
<cr>
Example
SYST:DEL
internal/program/program_1.xml
SYST:DEL
“
internal/program/program_1.xml”
SYST:DEL temporal/program/program_1.xml
SYST:DEL “temporal/program/program_1.xml”
Query Format
none
Query Format
SYSTem:FILE:TYPE? <MEM>
Description
This command returns the file type in numeric available memory
types catalog.
Returned Data Format
<nr1>
Query Example
SYST:FILE:TYPE? RAM
0
SYST:FILE:TYPE? INTERNAL
0
Command Syntax
SYSTem:SCREENshot
Description
This command takes a screen shot of the LCD display. The LCD image
is saved as a “.png” format image file to folder “internal/screenshots”
Parameters
None
Parameter Format
N/A
Example
SYST:SCREEN
Query Format
none
Summary of Contents for AFX Series
Page 484: ......