AFX SERIES® OPERATION MANUAL
Rear Panel, Connectors and Protection
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 209 of 485
7.3.13.4
Digital Inputs
Digital Inputs allow external equipment such as PLCs. to control the power source operation.
The assignment functions to each available input can be configured from the front panel.
Available settings are:
•
CHANNEL
[ 1 | 2 | 3 ]
•
STATE
Displays input state
•
RISING CMD
Set command string to execute on rising edge
•
FALLING CMD
Set command string to execute on falling edge
•
FILTER SIZE
0 to 10,000,000 msec
7.3.13.5
Digital Outputs
Digital Outputs can be used to trigger or control external equipment. The events assignable
to each digital output can be selected using the
Function
field.
Available settings are:
•
CHANNEL
[ 1 | 2 | 3 | 4 ]
•
STATE
Displays current state
•
FUNCTION
Assigns state to selected channel. Available states are:
•
INV. LOGIC
[ ON | OFF ] Reverses polarity