AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 370 of 485
Query Format
SYSTem:AIO:OUTput[n]:OFFSET:DEFault?
Description
Returns the default offset for the specified analog output port.
Parameters
None
Returned Data Format
n/a
Query Example
SYST:AIO:OUT1:OFFSET:DEF?
0.00000
Query Format
SYSTem:AIO:OUTput[n]:OFFSET:MAXimum?
Description
Returns the maximum gain for the specified analog output port.
Parameters
None
Returned Data Format
n/a
Query Example
SYST:AIO:OUT1:GAIN:MAX?
100000.00000
Query Format
SYSTem:AIO:OUTput[n]:OFFSET:MINimum?
Description
Returns the minimum gain for the specified analog output port.
Parameters
None
Returned Data Format
n/a
Query Example
SYST:AIO:OUT1:GAIN:MIN?
-100000.00000
Command Syntax
SYSTem:AI:OUTput[n]:GAIN <nr2>
Description
Sets the full-scale gain of the specified analog output port.
Parameters
Full scale value
Parameter Format
<nr2>
Example
SYST:AIO:OUT1:GAIN 230.0
Query Format
SYSTem:AIO:OUTput[n]:GAIN?
Returned Data Format
<nr2>
Query Example
SYST:AIO:OUT1:GAIN?
230.00
Query Format
SYSTem:AIO:OUTput[n]:GAIN:DEFault?
Description
Returns the default full-scale gain for the specified analog output.
Parameters
None
Returned Data Format
<nr2>
Query Example
SYST:AIO:OUT1:GAIN:DEF?
425.00000
Query Format
SYSTem:AIO:OUTput[n]:GAIN:MAXimum?
Description
Returns the maximum full-scale gain for the specified analog output.
Parameters
None
Returned Data Format
n/a
Query Example
SYST:AIO:OUT1:GAIN:MAX?
100000.00000
Summary of Contents for AFX Series