AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 327 of 485
Query Syntax
[SOURce:]PULSe:VOLTage:DC#:DEFault?
Description
This command returns the default set value for the initial PULSE
voltage for selected phase # or for all phases if phase reference is
omitted
Returned Data Format
<nr2>
Query Example
PULS:VOLT:DC1:DEF?
0.000,0.000,0.000
Command Syntax
[SOURce:]PULSe:FREQuency < nr2 >, <cr>
Description
This command sets the PULSE frequency.
Parameters
Voltage , < NORmal | SATurate >
Default is NORmal if optional second parameter is omitted.
Parameter Format
<nr2>, <cr>
Example
PULS:FREQ 50.00
Query Format
[SOURce:]PULSe:FREQuency?
Returned Data Format
<nr2>
Query Example
PULS:FREQ?
60.0000
Query Syntax
[SOURce:]PULSe:FREQuency:MINimum?
Description
This command returns the minimum permissible set value for the
PULSE frequency.
Returned Data Format
<nr2>
Query Example
PULS:FREQ:MIN?
15.0000
Query Syntax
[SOURce:]PULSe:FREQuency:MAXimum?
Description
This command returns the maximum permissible set value for the
PULSE frequency.
Returned Data Format
<nr2>
Query Example
PULS:FREQ:MIN?
1200.0000
Query Syntax
[SOURce:]PULSe:FREQuency:DEFault?
Description
This command returns the default set value for the initial PULSE
frequency.
Returned Data Format
<nr2>
Query Example
PULS:FREQ:DEF?
60.0000