AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 322 of 485
Command Syntax
[SOURce:]PULSe:DCYCle
<nr1>, <opt>
Description
This command sets the pulse duty cycle in percent. Minimum set
value allowed is 1, max is 99.
Parameters
Duty Cycle %, Option: < NORmal | SATurate >
Default is NORmal if optional second parameter is omitted.
Parameter Format
<nr1>, <cr>
Example
PULS:DCYC 50
Query Format
[SOURce:]PULSe:DCYCle?
Returned Data Format
<nr1>
Query Example
PULS:DCYC?
50.0000
Query Syntax
[SOURce:]PULSe:DCYCle:MINimum?
Description
This command returns the minimum permissible set value for the
PULSE duty cycle.
Returned Data Format
<nr2>
Query Example
PULS:DCYC:MIN?
0.0000
Query Syntax
[SOURce:]PULSe:DCYCle:MAXimum?
Description
This command returns the maximum permissible set valuefor the
PULSE duty cycle.
Returned Data Format
<nr2>
Query Example
PULS:DCYC:MAX?
100.0000
Query Syntax
[SOURce:]PULSe:DCYCle:DEFault?
Description
This command returns the default set value for the PULSE duty cycle.
Returned Data Format
<nr2>
Query Example
PULS:DCYC:DEF?
50.0000
Command Syntax
[SOURce:]PULSe:PERiod <nr2>, <opt>
Description
This command sets the pulse period in seconds.
Parameters
Period, Option: < NORmal | SATurate >
Default is NORmal if optional second parameter is omitted.
Parameter Format
<nr2>, <cr>
Example
PULS:PER 12.8
Query Format
[SOURce:]PULSe:PERiod?
Returned Data Format
<nr2>
Query Example
PULS:PER?
12.8000
Summary of Contents for AFX Series